Madu Citra

(021) 5890 8591

Monday - Friday: 08:30 - 17:00

Home Service Tentang Kami Industri Kontak
Hubungi Kami
Minecom Leaky Feeder

SINGLE BRANCH UNIT

Model Seri: SINGLE-BRANCH-UNIT

Kategori: Minecom Leaky Feeder

Hubungi Kami

Konsultasikan kebutuhan radio komunikasi Anda dengan tim teknisi ahli kami secara langsung untuk mendapatkan penawaran terbaik.

OVERVIEW & SPESIFIKASI

MODEL 02-00030 SINGLE BRANCH UNIT PBE's Minecom Single Branch Unit is a passive device used to branch off (one input, two outputs) the main Leaky Feeder cable into a side tunnel or another level. Single Branch Unit provide a balanced RF output with a minimum of a!enua"on and voltage loss through the branch and passes DC voltage from Power Coupler to amplifiers. PBE's Minecom Single Branch Unit u"lizes Minecom's proprietary Leaky Feeder terminal and saddle connec"ons rather than coaxial connectors (which can cause higher voltage drops and present challenges to installa"on and field maintenance). The device is configurable and provides the following se3ngs which can be selected during installa"on: • Passes both RF and DC to the branch (normal opera"on) • Isolate or terminate the branch (blocks both RF and DC from entering the branch cable) • Isolate DC in the port (blocks DC from entering the branch cable). FEATURES • Compa"ble with Voice and Data communica"ons • Saddle and Clamp connec"ons • Minimum IP55/NEMA4X rated enclosure • 2 x Internal isola"on jumpers INSTALLATION PBE's Minecom Single Branch Units are designed for easy assembly underground without the need for specialized tools or skills. Branch Units introduce some losses into the system ranging from 4 dB to 8 dB, depending upon the signal path and frequency. The Minecom System Design drawing (01-20000-05 for VHF or 01-30001-05 for UHF) should be used to account for losses of installed Branch Units. The length of cable would reduce if a second Branch Unit were to be inserted between the same two amplifiers. SPECIFICATIONS Frequency range: 100 – 500 MHz (Minecom VHF & UHF systems) Output to Output Isola.on: -10 dB minimum Inser.on Loss: Base to Tunnel: Base to Branch 1: VHF: 5 dB +/- 0.5 dB VHF: 4 dB +/- 0.5 dB UHF: 8 dB +/- 0.5 dB UHF: 7.5 dB +/- 0.5 dB Impedance: 75 ohm System Voltage Range: 12 – 48 V DC Through Current Capacity: 1.5 amps maximum Power Requirements: None Connec.ons: Saddle and clamp Enclosure: IP55/NEMA4X heavy duty enclosure Weight & Dimensions: 1.1kg; 215 (w) x 110 (d) x 65 (h) mm (2 lb 7 oz; 8.5 (w) x 4.3 (d) x 2.6 (h) inches)    
© 2013 CV Maducitracom. All Rights Reserved.
Online: 1
Kemarin: 312
Total: 19,073
Kebijakan Privasi Syarat Layanan
WhatsApp